Introduction to electrocardiogram signal quality assessment and estimated accuracy for textile electrodes

As the use of wearable electrocardiogram (ECG) data for modeling purposes continues to rise, there is a pressing need for signal quality assessment (SQA) algorithms capable of identifying segments of signal from which reliable data can be obtained. Manually annotated ECG data, obtained through expert visual inspection, is often used as reference in the development of ECG SQA algorithms. In this approach, the quality of a signal segment is assessed based on the level of noise present. Yet, the data extracted from noise-corrupted ECG signal segments might still be of sufficient accuracy depending on the target application. The current work proposes a paradigm shift by presenting a SQA algorithm that performs template matching and physiological feasibility checks to determine the quality of ECG signals acquired by textile-based wearable systems. Signal segments were classified into four different quality classes based on the estimated accuracy of RR intervals extracted from the signal segments of each class. Our findings show that the proposed SQA algorithm is effective in identifying ECG signal segments from which accurate RR intervals can be derived, and that the proportion of the data across the different classes is sensitive to different factors known to have an effect on signal quality.

Executive Impact: Precision in Health Monitoring

The research introduces a paradigm-shifting approach to ECG signal quality, focusing on data accuracy rather than mere signal cleanness. This enables more reliable health monitoring, especially with wearable devices, leading to better diagnostic and intervention strategies.

0 Accurate RR Intervals (Classes 1 & 2)
0 Usable Data from Class 3 Segments
0 Class 4 Segments (Discard for RR)

Deep Analysis & Enterprise Applications

Select a topic to dive deeper, then explore the specific findings from the research, rebuilt as interactive, enterprise-focused modules.

ECG Signal Quality Assessment Flow

Input signal split into 15-second segments (1-sec overlap)
R-wave detection & QRS/PQRST complex extraction
Template generation by averaging individual complexes
Pearson correlation & RR interval plausibility checks
Classification into 4 quality classes based on r-values and plausibility

Estimated RR Interval Accuracy

99.7% Average accuracy for Class 1 & 2 RR intervals

Our findings demonstrate that over 99% of signal segments in classes 1 and 2 accurately estimate RR intervals, essential for reliable cardiovascular analysis. Even Class 3 maintains 86.6% accuracy, expanding the usable data pool.

Quality Class RR Mean Difference [ms] SRR Mean Difference [ms] % Segments Meeting Equality Criteria
Class 1 0.15 ± 0.87 0.44 ± 1.75 99.90
Class 2 0.25 ± 2.06 0.57 ± 2.70 99.71
Class 3 4.59 ± 22.83 8.69 ± 20.68 86.61
Class 4 344.71 ± 246.47 99.25 ± 96.98 1.02

Monitoring Setting Challenges: Inpatient vs. Outpatient

Scenario: Wearable ECG systems are used in diverse environments, from controlled inpatient settings to less supervised outpatient (home) monitoring.

Challenge: Inpatient multi-parameter belts yield less Class 1 data and more Class 2/4 compared to gel electrodes. Outpatient settings further amplify this, leading to a significant increase in Class 4 data (median 16.51% vs. 2.57% inpatient), due to reduced supervision and environmental noise.

Solution: The SQA algorithm dynamically assesses signal quality, allowing identification and utilization of valid data even from challenging outpatient recordings. This maximizes the usable data for continuous monitoring, enabling early detection of changes in patient trends.

Outcome: By providing estimated accuracy per quality class, the system allows clinicians to confidently use data from different settings for appropriate applications, even when signals are not 'noise-free,' facilitating real-world, long-term health monitoring.

Movement Artifacts & Signal Quality Degradation

Scenario: Patients' body movements and positions inherently affect electrode-skin contact and signal integrity in wearable ECG monitoring.

Challenge: Even minor movements (jerk up to 50 mg/s, e.g., bicycle riding) significantly reduce Class 1 data and increase Class 4. During physical activity, Class 1 data from monitoring belts can drop to 0% from 34.7%, highlighting severe degradation.

Solution: The SQA algorithm, incorporating template matching and physiological feasibility checks, effectively filters out heavily corrupted segments while preserving segments where RR intervals can still be accurately derived, despite visible noise.

Outcome: This approach enables continuous, reliable heart activity monitoring during daily life, ensuring that crucial physiological data can still be extracted and analyzed even in the presence of typical motion artifacts, expanding the applicability of wearable ECG.

Redefining SQA: Accuracy Over Cleanliness

Impactful Shift in Signal Quality Assessment

The study champions a paradigm shift from assessing ECG signal quality based on visual 'cleanness' to evaluating the 'estimated accuracy' of derived data (e.g., RR intervals). This re-focus maximizes the utility of wearable ECG data, enabling robust analysis even from noisy signals.

Advanced ROI Calculator

Estimate the potential return on investment for implementing an AI-powered ECG analysis system in your enterprise.

Estimated Annual Savings
Annual Hours Reclaimed

Your AI Implementation Roadmap

A typical phased approach to integrating advanced AI ECG analysis into your existing enterprise infrastructure.

Phase 1: Discovery & Strategy

Comprehensive assessment of current ECG monitoring workflows, data sources, and desired outcomes. Define project scope, KPIs, and technology requirements.

Phase 2: Pilot & Customization

Deploy a tailored AI model on a subset of data or a specific use case. Customize the SQA algorithm for textile electrodes and integrate with existing systems for initial validation.

Phase 3: Integration & Training

Full-scale integration of the AI system, including data pipelines for wearable devices. Train medical staff and technical teams on new protocols and data interpretation.

Phase 4: Optimization & Expansion

Continuous monitoring and refinement of AI performance based on real-world feedback. Explore expansion to new patient cohorts, diseases, or integration with other physiological data.

Ready to Transform Your ECG Analysis?

Leverage cutting-edge AI to enhance the accuracy and reliability of wearable ECG monitoring. Book a consultation to discuss how our solutions can benefit your organization.